3 research outputs found

    State-of-the-art MR imaging in the work-up of primary hepatocellular tumors

    Get PDF
    Magnetic resonance (MR) imaging is an imaging modality that has evolved rapidly in the past two decades. The development of advanced hardware and new sophisticated pulse sequences have allowed faster imaging, with increased temporal and spatial resolution. This has resulted in the development and implementation of new acquisition techniques that facilitate improved visualisation of neoplastic processes. In addition, faster sequences enable multiphasic dynamic imaging after intravenous administration of contrast material, which results in better tumor characterisation and improved diagnostic confidence by the reading radiologist. The radiol

    Twelve week liraglutide or sitagliptin does not affect hepatic fat in type 2 diabetes: a randomised placebo-controlled trial

    Get PDF
    _Aims/hypothesis:_ Glucagon-like peptide (GLP)-1-based therapies have been suggested to improve hepatic steatosis. We assessed the effects of the GLP-1 receptor agonist liraglutide and the dipeptidyl peptidase (DPP)-4 inhibitor sitagliptin on hepatic steatosis and fibrosis in patients with type 2 diabetes. _Methods:_ In this 12 week, parallel, randomised, placebo-controlled trial, performed at the VU University Medical Center between July 2013 and August 2015, 52 overweight patients with type 2 diabetes treated with metformin and/or sulphonylurea agent ([mean ± SD] age 62.7 ± 6.9 years, HbA1c 7.3 ± 0.7% or 56 ± 1 mmol/mol) were allocated to once daily liraglutide 1.8 mg (n = 17), sitagliptin 100 mg (n = 18) or matching placebos (n = 1

    Liver imaging at 3.0 T: Diffusion-induced black-blood echo-planar imaging with large anatomic volumetric coverage as an alternative for specific absorption rate-intensive echo-train spin-echo sequences: Feasibility study

    No full text
    Institutional Review Board approval and signed informed consent were obtained by all participants for an ongoing sequence optimization project at 3.0 T. The purpose of this study was to evaluate breath-hold diffusion-induced blackblood echo-planar imaging (BBEPI) as a potential alternative for specific absorption rate (SAR)-intensive spin-echo sequences, in particular, the fast spin-echo (FSE) sequences, at 3.0 T. Fourteen healthy volunteers (seven men, seven women; mean age ± standard deviation, 32.7 years ± 6.8) were imaged for this purpose. Liver coverage (20 cm, z-axis) was always performed in one 25-second breath hold. Imaging parameters were varied interactively with regard to echo time, diffusion b value, and voxel size. Images were evaluated and compared with fat-suppressed T2-weighted FSE images for image quality, liver delineation, geometric distortions, fat suppression, suppression of the blood signal, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). An optimized short- (25 msec) and long-echo (80 msec) BBEPI provided full anatomic, single breath-hold liver coverage (100 and 50 sections, respectively), with resulting voxel sizes of 3.3 x 2.7 x 2.0 mm and 3.3 x 2.7 x 4.0 mm, respectively. Repetition time was 6300 msec, matrix size was 160 x 192, and an acceleration factor of 2.00 was used. b Values of more than 20 sec/mm2showed better suppression of the blood signal but b values of 10 sec/mm2provided improved volume coverage and signal consistency. Compared with fat-suppressed T2-weighted FSE, the optimized BBEPI sequence provided (a) comparable image quality and liver delineation, (b) acceptable geometric distortions, (c) improved suppression of fat and blood signals, and (d) high CNR and SNR. BBEPI is feasible for fast, low-SAR, thin-section morphologic imaging of the entire liver in a single breath hold at 3.0 T
    corecore